Active Harmonic Filtering
banner

SNA-AHF-W

AHF Active Harmonic Filter

  • ltem NO.:
    SNA-AHF
  • Order (MOQ):
    1
  • Weight:
    25~50kg
  • Rated capacity:
    30A, 50A, 75A, 100A, 150A
  • HMI:
    4", 7", 10" optional
Description

How does an AHF work?

An active harmonic filter has a measurement system that "listens" for noise in the power system and generates a compensating current to cancel out that which is less than ideal. It uses active technology to reduce unwanted harmonic distortion, correct power factor and improve the voltage regulation and unbalance of the power grid.

 

Main Compensation Modes

An active harmonic filter has a measurement system that "listens" for noise in the power system and generates a compensating current to cancel out that which is less than ideal. It uses active technology to reduce unwanted harmonic distortion, correct power factor and improve the voltage regulation and unbalance of the power grid.

Power factor correction
Corrects power factor by injecting a forward or reverse current to counter act reactive power in the system. This helps improve energy efficiency and reduce energy costs
Harmonic distortion
Eliminate harmonic distortion by detecting harmonic current and injecting acorresponding current in the opposite direction. This helps improve power quality and protect equipment from damage.
Voltage unbalance
AHF can balance currents and reduce voltage unbalance caused by uneven loads. However, it may not fully correct unbalance originating from upstream supply faults or severely unequal network.

 

 

Main functions

 

  • Harmonic-current reduction
  • Reactive-power compensation
  • Power-factor improvement
  • Three-phase load balancing
  • Neutral-current reduction
  • Dynamic compensation for changing loads
Advantages

Compared with passive harmonic filters, an AHF offers:

  • Millisecond-level response
  • Dynamic and precise compensation
  • Compensation of multiple harmonic orders
  • Lower resonance risk
  • Adaptability to changing loads
  • Selectable compensation priorities
  • Easy parallel capacity expansion
Technical

Specification

An active harmonic filter has a measurement system that "listens" for noise in the power system and generates a compensating current to cancel out that which is less than ideal. It uses active technology to reduce unwanted harmonic distortion, correct power factor and improve the voltage regulation and unbalance of the power grid.

 

  220V, 400V   3P3W/3P4W 480V, 550V, 690V   3P3W
Mounting type Wall mounted Rack mounted Rack mounted
Network voltage range ±10%
Nominal current (A) 15/30/50/75/100/150 50/100
Frequency 50/60Hz (±5%)
Harmonic compensation 2nd ~ 51st harmonic order
Efficiency ≥97%
Response time <10ms
Circuit topology Three-level topology
Switching frequency 20 kHz - Reaction time: Approximately 50 ps
Parallel operation Maximum of 20 units can be combined
Typical power loss <3% (depending on the load)
Compensation mode Harmonic, reactive power, unbalance
Target power factor Adjustable from -1 to 1
Display 4.3inch/7inch/10 inch HMI
Communication ports RS485 / Ethernet
Noise level ≤65dB
Operating Temperature -20℃ to 45 ℃
Humidity 5% to 95% RH, non-condensing
Protection class IP20
Design/Approvals EN 61000-6-2:2005+AC:2005 EN 61000-6-4:2007+A1:2011
 EN 50178:1997 IEEE519
Certification CE