ACB
banner

KW2

ACB Air Circuit Breaker

  • Rated current(In):
    200A~4000A
  • Rated voltage(Ue):
    690V or below
  • Ultimated Breaking capacity(Icu):
    65KA (200~1600A) / 100kA (800~4000A)
  • Operate breaking capacity(Ics):
    50kA (200~1600A) / 100kA (800~4000A)
  • Frequency:
    50/60Hz
  • Electrical life:
    6000
  • Mechanical life:
    10000~20000ccC
  • Certificate:
    CCC,CE,CB
Description

KW2 Air Circuit Breaker

KW2 Air Circuit Breaker provides protection of overload, short circuit and single phase earth with intelligent and selective protection function, the breaker can improve the reliability of power supply and avoid unnecessary power fail. It's applicable for power stations, factories, and modem high-buildings, etc., especialy for the distribution system of intelligent building.

 

Product type: Air Circuit Breaker

Product series: KW2

Product application: High current power circuit protection

Number of poles: 3P, 4P

Applicable category: B

Rated current (ln): 400-4000A

Rated operating voltage (Ue): AC240V / 400V / AC500V / 690V

Rated insulation voltage (Ui): AC1000V

Rated impulse withstand voltage (Uimp): 12KV

Tripping unit: Electronic intelligent controller

Communication:Modbus RS485 (Optional)

 

Breaking capacity:

 

 

KW2-4000

 

AC240V/400V,Icu=120kA  Ics=100kA  Icw=100kA,1s / 85kA,3s

AC690V   Icu=85kA  Ics=85kA  Icw=85kA,3s


KW2-1600

 

AC240V/400V,Icu=65kA   Ics=50kA   Icw=50kA,1s

AC690V Icu=35kA   Ics=35kA   Icw=35kA, 3s

 

Standard: IEC 60947-2, EN 60947-2, IEC 60947-3, EN 60947-3, GB/T 14048.2, AS/NZS 60947.2

Certificate: CCC CE CB

 

KW2 Air Circuit Breaker

 

The circuit breaker can be racked in/out of the chassis with three position locking:

 

KW2 Air Circuit Breaker

Time Delayed Short Circuit Protection Characteristic

KW2 Air Circuit Breaker

Adjustable Setting 
1. Overload Current setting (Ir)
2. Overload Long-Delay Time (t1)
3. Short-circuit Current setting (Is)
4. Short-circuit Short-Delay Time (t2)
5. Instantaneous Trip Current setting (Isd)

 

 

Ground Fault Protection Characteristics (Optional)

KW2 Air Circuit Breaker

1. Ground Fault Current setting (Ig)
2. Ground Fault Delay Time (t3)
3. Alarm and no-break Function (Optional)

 

 

Residual Earth Leakage Protection Characteristics (Optional)

KW2 Air Circuit Breaker

1. Residual Earth Leakage Current setting (I△n)
2. Residual earth leakage Delay Time (t△n)

Loads monitoring

KW2 Air Circuit Breaker


- Programmable control unit monitors the loads to ensure power supply.
- Two types of monitoring for option. The current thresholds are Ic1 and Ic2. normally Ic1 ≥ Ic2.

Control unit time/current characteristics curves

2000A

KW2 Air Circuit Breaker

Control unit time/current characteristics curves

5000A

KW2 Air Circuit Breaker

Technical
Type KW2-1600 KW2-4000
Frame  size  Inm(A) 1600  4000 
Rated current  In(A) 200/315/400/630/800/1000/1250/1600 800/1000/1250/1600/2000/2500/3200/4000
Rated  operation  voltage  Ue(V) AC 240/400/500/690V 50/60Hz
Rate insulation voltage Ui(V) AC 1000
Rated Impulse withstand voltage Uimp(V) 12000 
Power frequency withstand voltage(V) AC 2500V 1min 50Hz
Number of pole 3/4
N pole rate current In(A) 100%In
Utimate breaking capacity Icu(kA)VAC50/60Hz 240/400V 65  100 
500/690V 35  85 
Rated operating breaking capacity Ics(kA)VAC 50/60Hz 240/400V 50  100 
500/690V 35  85 
Rate making capacity(Peak)
Icm(KA)
240/400V 143  187 
500/690V 143  220 

Rate short-time withstand current (1s/3s)Icw(kA)

50/35 100/85
Intelligent control Unit ST3.0/3.2H
No of operationg
cycles
Electricallife 6000  2000 
Mechacnciallife without  maintenance 10000  10000 
with maintenance 20000  20000 
Connection Type Terminals Horizontal Vertical Horizontal Vertical
Draw-out Type O O O O
FixType O O O O
Size H×W×D 3P Draw-out Type 350(H)×282(W)x 300(D) 430(H)x407(W)×395(D)
4P Draw-out Type 350(H)×352(W)x 300(D) 430(H)×512(W)×395(D)
3P Fixed Type 350(H)×266(W)x200(D) 393(H)x422(W)×290(D)
4P Fixed Type 350(H)×336(W)x200(D) 393(H)×537(W)×290(D)
Characteristics

Long-time overload protection (IDMTL setting)

KW2 Air Circuit Breaker

 

Short-time Short-circuit protection

KW2 Air Circuit Breaker

 

Instantaneous protection against short-circuit characteristic

KW2 Air Circuit Breaker

Earthfaults protection characteristic

KW2 Air Circuit Breaker

Residual earthleakage protection characteristic

KW2 Air Circuit Breaker

Load Monitoring Characteristics

KW2 Air Circuit Breaker